RESmart AutoCPAP BMC-630A

RESmart® Auto (APAP) adopts advanced sensor technology, automatically tracking patients' respiratory condition. The intelligent control system provides patients the reliable therapy of Obstructive Sleep Apnea (OSA).

Professional precision

  • » Innovative tracking technology ensures accurate and comfortable therapy.
  • » Unique sensitivity setting offers individual therapy algorithm, makes every user get the most comfort.
  • » RESlexTM performs better exhalation and compliance.
  • » Inspiration trigger for auto start-up
  • » Automatic stop after put off mask
  • » Alert when accidental power-off
  • » In time alert function when mask/tubing off-line
  • » Automatic leakage and altitude compensation ensure the therapy accuracy anywhere.

Ergonomic and powerful design

  • » Integrated and knock-down designed InH2TM heated humidifier
  • » DC 24V powered and infrared controlled humidifier make user safe and comfortable.
  • » Smart Heater automatic restarts after short term break.
  • » Patented anti-countercurrent water tank
  • » Unique Delay-off feature protects RESmart® Auto from humidity hazard.
  • » Powerful embedded memory stores last night’s full raw data, 365 nights’ user Blog and more than 30 years’ therapy record.
  • » User Blog direct output via portable thermal printer


  • Specification
  • Gallery

Technical Specifications:

Device Size


Dimensions: Weight:
220 × 194 × 112 mm
313 × 194 × 112 mm (with InH2TM heated humidifier)
1.6 kg
2.4 kg(with InH2TM heated humidifier)

Product Use, Transport and Storage

Operation : Transport and Storage:
Temperature: 5 to 40℃ -20 to 55℃
Humidity: 80% Non-condensing 93% Non-condensing
Atmospheric Pressure: 860 to 1060 hPa 500 to 1060 hPa

Standard Compliance

       IEC 60601-1 General Requirements for Safety of Medical Electrical Equipment

       ISO 17510 Sleep Apnoea Breathing Therapy

Mode of Operation

       Continuous

AC Power Consumption

       100 – 240VAC, 50/60Hz

Type of Protection Against Electric Shock

       Class II Equipment

Degree of Protection Against Electric Shock

       Type BF Applied Part

Degree of Protection Against Ingress of Water

       IPX1 – Drip-Proof, Vertical

PressureRange

       4 to 20 hPa (in 0.5 hPa increments)

Pressure Stability

       4 to 20 hPa (±0.5 hPa)

Sound Pressure Level

       30 dBwhen the device is working at the pressure of 10 hPa

Maximum Flow

       35 LPM

Pressure Display Accy.

       ±0.5 hPa

 

NOTE: specifications subject to change without prior notice.