RESmart BPAP Bi-level Positive Airway Pressure BMC-730

RESmart® BPAP Series offers the ultimate in sleep therapy comfort. It combines auto adjusting pressure delivery with the breath-by-breath pressure relief of RESlexTM for most natural sleep therapy. It also can provide non-invasive ventilation for patients with respiratory insufficiency in the hospital or home.

Professional precision

  • » Innovative tracking technology ensures accurate and comfortable therapy.
  • » Unique sensitivity setting offers individual therapy algorithm, makes every user get the most comfort.
  • » RESlexTM performs better exhalation and compliance.
  • » Inspiration trigger for auto start-up
  • » Automatic stop after put off mask
  • » Alert when accidental power-off
  • » In time alert function when mask/tubing off-line
  • » Automatic leakage and altitude compensation ensure the therapy accuracy anywhere.

Ergonomic and powerful design

  • » Integrated and knock-down designed InH2TM heated humidifier
  • » DC 24V powered and infrared controlled humidifier make user safe and comfortable.
  • » Smart Heater automatic restarts after short term break.
  • » Patented anti-countercurrent water tank
  • » Unique Delay-off feature protects RESmart® BPAP from humidity hazard.
  • » Powerful embedded memory stores last night’s full raw data, 365 nights’ user Blog and more than 30 years’ therapy record.
  • » User Blog direct output via portable thermal printer


  • Specification
  • Gallery

Technical Specifications:

Device Size


Dimensions: Weight:
220 × 194 × 112 mm
313 × 194 × 112 mm (with InH2TM heated humidifier)
2.2 kg
3 kg (with InH2TM heated humidifier)

Environmental

 

Operating: Transport and Storage:
Temperature 5 to 30°C -20 to 55°C
Relative Humidity 80% Non-condensing 93% Non-condensing
Atmospheric Pressure 860 to 1060 hPa 500 to 1060 hPa

 

Standards Compliance

IEC 60601-1 General Requirements for Safety of Medical Electrical Equipment

IEC 60601-1-2 Electromagnetic Compatibility

ISO 17510 Sleep Apnoea Breathing Therapy

ISO 8185 General Requirements for Humidification Systems

Electrical

AC Power Consumption:    100 - 240V AC, 50/60Hz, Max 95VA

Type of Protection Against Electric Shock:    Class II Equipment

Degree of Protection Against Electric Shock:       Type BF Applied Part

Degree of Protection Against Ingress of Water:   Drip Proof, IPX1

Mode of Operation:    Continuous

Model Comparison

 

Product Model Pressure Function Auto Pressure
RESmart® BPAP 25 4-25cmH2O S, CPAP No
RESmart® BPAP 25A 4-25cmH2O S, CPAP available
RESmart® BPAP 25T 4-25cmH2O S, CPAP, T, S/T No
RESmart® BPAP 30T 4-30cmH2O S, CPAP, T, S/T No

Pressure

IPAP 4 to 30 cmH2O* ±1 cmH2O**
EPAP 4 to 25 cmH2O* ±1 cmH2O**
CPAP 4 to 20 cmH2O ±1 cmH2O**
Respiratory Rate 3 to 40 BPM, Greater of ±1 BPM or ±10% of the setting
(When measured over a 4 minutes period)
E/I Rate 1-4
Max. Inspiration Time 3.0 seconds
Ramp Duration 0 to 60 minutes ±10% of the setting
Rise Time 0 to 3*** ±25%****

* Limited to 20 cmH2O when using the Auto feature in S mode.

** Dynamic pressure accuracy is ±1 cmH2O measured at the patient end of the circuit with a Vio Nasal Mask and varying flow conditions.

Static pressure accuracy is ±0.5 cmH2O measured at the patient end of the circuit with a Vio Nasal Mask and no patient flow.

*** The range of values corresponds to tenths of seconds (e.g., a setting of 4 indicates a Rise Time of 0.4 seconds).

**** Measured at the patient end of circuit with a Vio Nasal Mask exhalation device and no patient flow.

Disposal

Dispose of the device in accordance with local regulations.

 

Manufacturer: BMC Medical Co., Ltd.

NOTE: specifications subject to change without prior notice.